Low Prices on Popular Products. High Quality Fire Safety Equipment. Fire exit signs regulations stipulate that it is the duty of the employer to ensure that there are adequate health and safety signs provided wherever there is a risk to an employee’s health and safety. The fire risk assessment will identify and show the need for fire exit signs in your property.


Illuminated fire escape route signs and fire exit signs fulfil this requirement.

The minimum backup duration of emergency lighting as specified by regulations is generally between and hours. For more information on emergency lighting see our emergenc. Fire safety warning signs , fire exit signs and fire -fighting equipment are also covered. They require employers to provide specific safety signs whenever there is a risk that has not been avoided or controlled by other means, e. Does the RA depict this or are they only to be illuminated in hard to see areas?


Fire escape signs are not needed on the main route into or out of a building (the one used by people for normal arrival and exit ), but alternative escape routes and complicated escape routes do need to be signed. Our range of illuminated fire exit signs use the standardised designs required throughout the UK so that both staff and members of the.

Ensure that your property is correctly signed with our range of fire exit signage, illuminated fire exit signs and more. View our fire safety signs here. Get Exit Signs Illuminated. Free UK Delivery on Eligible Orders! Tough and durable construction.


Comply with UK legislation. For example, signs with a potentially confusing message (eg ‘no thoroughfare’ and ‘ fire exit ’) should not be used in the same location. All changes of direction in corridors, doors, stairways and open spaces forming part of an escape route should be marked with intermediate signs.


Fire Exit Arrow Down – To be used when you have to continue along your route, towards another fire exit sign. If after an exit sign there is a staircase leading down immediately after your sign, then a down arrow is required. Exit signs – internally illuminated and Photoluminescent signs A previous article considered the basic requirements for externally illuminated exit signs. Exit signs must be properly illuminated by a reliable light source, with a minimum of foot-candles on the illuminated surface. Ambient lights sources giving illumination to exit signs other than the Electrical Exit signs must have screens, discs, or lenses of not less than square inches area made of translucent material to confirm Contrast.


All exit routes should be clearly marked using signs that comply with the current fire regulations. The most important thing about modern exit signs is that they all include a graphic symbol.

Signs that do not include this symbol and simply have words on them are now no longer legal, and need to be updated. Externally illuminated refers to a source of illumination that comes from outside the exit sign while internally illuminated exit signs possess the illumination source inside the sign. For externally illuminated signs , the Life Safety Code section 7. Exit Signs We offer a wide range of fire exit signs at various viewing distances for installation in an emergency escape lighting system.


When a fire or natural disaster leaves buildings without power, these signs remain intact and illuminated , guiding those inside to safety. In this article, we’ll explain what life safety code and federal law expect from exit signs and emergency lights. Fire Exit Signs (products) Fire safety legislation states that fire exit signs with an arrow must be used to clearly indicate the direction of an escape route and exit. Internally illuminated signs required by 5-10.


EXIT ” or other appropriate wording in letters legible from a distance of at least 1ft (m) under all normal and emergency Lighting conditions (fc and fc, respectively). The legislation requires all duty holders to ensure that the means of escape is effectively located and the route to a place of relative safety be clearly identified. Manufactured from screen printed rigid 3mm white Foamex, either single or double sided and suspended with a satin anodised aluminium extrusion.


The emergency fire escape signs you use to indicate the means of escape on site, including illuminated fire escape signs is now an international standard. In low-light areas your signs may need to be illuminated to ensure that they can be clearly seen by all and that they meet the necessary UK fire exit signs regulations. If your business premises require emergency lighting, then your fire exit signs have to be illuminated as well, either with external or internal lamps or with self-illuminating signs which don’t require an external power.